Electrical Engineering

Laboratory Details of Electrical Engineering

S. No. Name of Laboratory Available
1 High Voltage Laboratory (C-11)
2 COMPUTER APPLICATION LABORATORY:- C-12
3 Basic Electrical Laboratory: - C-13
4 CONTROL SYSTEM LAB :- C-14
5 POWER ELECTRONICS LAB :-C-14
6 Electrical Measurement Laboratory: - C-15
7 Network Theory Laboratory: - C-15
8 PG RESEARCH LAB (C-16)
9 ELECTRICAL MACHINES LAB:- C-22
10 Switch Gear and Protection Lab :-C-23
11 Electric Drives Laboratory : C-23
12 Workshop Laboratory: - C-26
12 Microcontroller Laboratory :C-28
High Voltage Laboratory (C-11)

Name of the Laboratory:- High Voltage Engg. Laboratory 

  • Configuration of the devices available in the laboratory:-
  • V Test Transformer
  • Oil Test system for measurement of oil loss angle resistivity
  • Impulse Generator
  • of devices available in the laboratories:- 13
  • Lab utilization(Area of the Laboratory):- 93.70 Sqm2.
  • Project/ Practical conducted in the Laboratory.- High Voltage Practical
  • List of the Software available or installed in the laboratory.:-MATLAB & PSIM

Lab In-charge Details:- Prof.P.P.Jagtap

COMPUTER APPLICATION LABORATORY:- C-12
  • Project/ Practical conducted in the Laboratory:- CAIEE,AIML,CP,DSC,APTITUDE
  • Number of Apple MAC          : 20 units
  • Configuration                           : IOS & Windows
  • Area of the laboratory              : 90 m2
  • ETAP Power Station & PSCAD/EMTDC Software
  • PSCAD Software Single User
  • PSIM Software Five User
  • Matlab Software Version 6.0
  • Matlab Software Version 6.5
  • Matlab Software Version 6.5.1 
  • PSCAD Software 5 User, & Digital Fortan Version 6.6A
  • ETAP Software 5 user Version 5.0.3
  • SKM Power Tools & Power world

Lab In-charge Details : Er.Ankur Gupta

(M.Tech , VNIT ,NAGPUR)

Email Id: ankur.gupta@raisoni.net 

Contact No. 7385626267

Basic Electrical Laboratory: - C-13
  •  Name of the Laboratory:- Basic Electrical Engineering
  • Configuration of the devices available in the laboratory: - Dimmerstat, Ammeter, Voltmeter, Wattmeter, Transformer, Powersupply, Rheostat & Multimeter.
  • of devices available in the laboratories:- 41
  • Lab utilization(Area of the Laboratory):- 102 (Sqm.)
  • Project/ Practical conducted in the Laboratory:- Basic Electrical practical
  • List of the Software available or installed in the laboratory:- MATLAB & P-SIM Software

Lab In-charge Details :- Prof.P.S.Vaidya

CONTROL SYSTEM LAB :- C-14

Name of the Laboratory:- Control System Laboratory

Configuration of the devices available in the laboratory

  • D.C. Potentiometer kit : 1
  • Synchro receiver & Transmitter : 1
  • Stepper Motor/ Stepper Motor with 8085 up kit :2
  • D.C. Position Control System : 1
  • PID Controller : 1
  • Linear system simulator : 1
  • D.C. Speed control system : 1
  • CRO Dual Trace : 2
  • PC Based DC M. Speed Controller Setup : 1
  • Potentiometer Error Detector Kit : 1
  • Compensation Design kit : 1
  • Number of PC’s : 2
  • Configuration : Desktop PC with Pentium i3 processor 3.07 GHz,  4 GB DDR, 250GB

No. of devices available in the laboratories:-17

Lab utilization (Area of the Laboratory) 104 sq.m

Project/ Practical conducted in the Laboratory: Control System – I Practical

List of Software installed on all Computers: MATLAB

Lab In-charge Details : 

R.S. Hiware,  Assistant Professor, M.Tech IPS

POWER ELECTRONICS LAB :-C-14

  • Name of the Laboratory:- Power Electronics Laboratory

Configuration of the devices available in the laboratory:

  • Study of unijunction transistor : 1
  • Study of SCR and AC Phase control with Power supply   : 1
  • Study of TRIAC and AC phase control : 1
  • SCR Converters and Reactive load with power supply : 1
  • SCR DC circuit breaker: 1
  • Voltage commutated Chopper : 1
  • Current commutated Chopper : 1
  • Millimeter     : 9
  • Voltmeter : 3
  • Cathod Ray Osciloscope : 4
  • 1 phase cycloconverter  firing  ( Trigerring ) circuit .: 1
  • 1 phase cycloconverter  power circuit ( 25 Amp , 1200V) : 1
  • UJT Firing circuit using SCR : 1
  • SCR , TRAIC and DIAC characteristics : 2
  • Diac Characteristics : 1
  • Power MOSFET module : 1
  • IGBT  module : 1
  • Gate -Turn -Off ( GTO ) Thyrister module : 1
  • 3 Phase converter firing  circuit : 1
  • 3 Phase fully controlled converter power circuit : 1
  • 1 phase cycloconverter  ( Cetre Tap)  with   firing circuit, SCF : 1
  • 1 phase half controlled conveter power circuit  ( with firing circuit ) : 1
  •  Forced commutation study unit : 1
  • RHEOSTAT ( 5A/100ohm) : 3
  • Power Quality Analyzer : 1
  • SCR based DC shunt Motor 230V : 1
  • V/F Control of 3phase/1 Phase I.M : 1
  • 3 phase Converter Based DC Shunt Motor : 1
  • AC/DC Current Sensor(50), : 1
  • Invertor 800 VA : 1
  • DSO 2 CHANNEL : 1
  • DC POWER SUPPLY : 2
  • CRO POWER SCOPE :3
  • DSO 4 CHANNEL : 1
  • CURRENT PROBE FOR DSO 4 Channel : 3
  • VOLTAGE PROBE FOR DSO 4 Channel : 3
  • No. of devices available in the laboratories:-58

Lab utilization (Area of the Laboratory) -104 sq.m

Project/ Practical conducted in the Laboratory: Power Electronics Practical

Lab In-charge Details: Assistant Professor, V.P. Rajderkar, M.Tech (IPS)

Electrical Measurement Laboratory: - C-15

  • Name of the Laboratory:- Measurement Laboratory
  • Configuration of the devices available in the laboratory:- Dimmerstat, Transformer, Powersupply, Induction motor, Digital Multimeter, Dimmerstat, Ammeter.
  • of devices available in the laboratories:- 130
  • Lab utilization(Area of the Laboratory):- 102 (Sqm.)
  • Project/ Practical conducted in the Laboratory:- Electrical Measurement Practical
  • List of the Software available or installed in the laboratory:- MATLAB , P-SIM Software&Power World Simulator

Lab In-charge Details :- Prof. B.Karade

Network Theory Laboratory: - C-15

  • Name of the Laboratory:- Network Theory Laboratory
  • Configuration of the devices available in the laboratory:- Dimmerstat, Multimeter, Ammeter,Experimental Kit,Generator
  • of devices available in the laboratories:- 30
  • Lab utilization(Area of the Laboratory):- 102 (Sqm.)
  • Project/ Practical conducted in the Laboratory:- Network Theory Practical
  • List of the Software available or installed in the laboratory:- MATLAB , P-SIM Software & Power World Simulator

Lab In-charge Details :- Prof. R.S.Hiware

PG RESEARCH LAB   (C-16)

  • Name of the Laboratory:- PG RESEARCH LAB  
  • Configuration of the devices available in the laboratory:-
    • Simulation Panel (EHV-AC)
    • Hybrid Supercapacitor
    • MODROBS ( 3 Phase and single phase power line Analyzer with FACTS devices )
      3-Phase Shifting  Transformer
    • Simulation Panel (SVC)
    • Supercapator PBD (16.2V,58F.)
    • Three Phase FACTS Controller
    • Supercapacitor
    • Oscilloscope with powerscope
    • DELL Dual core computer set
    • Lenovo TFT computer set
    • UPS
  • of devices available in the laboratories:- 13
  • Lab utilization(Area of the Laboratory):- 74.45Sqm
  • Project/ Practical conducted in the Laboratory( PG RESEARCH LAB )  
  • List of the Software available or installed in the laboratory.:-MATLAB & PSIM

Lab In-charge Details:- Prof.K.D.Joshi

ELECTRICAL MACHINES LAB:- C-22

  • Name of the Laboratory:- Electrical Machines Lab (C-22)
  • Configuration of the devices available in the laboratory:- Digital Storage CRO, Rectifier Unit, DG Sets, Transformers & AC-DC motors.
  • of devices available in the laboratory :- 283.
  • Lab utilization (Area of the Laboratory):- 80.16 mm2.
  • Project/ Practical conducted in the Laboratory.:- Electric Machine-I & Electrical Machine-II
  • List of the Software available or installed in the laboratory.:- MATLAB& P-SIM

Lab In-charge Details:- Prof. R. H. Adware, (Assistant Professor)

Switch Gear and Protection Lab :-C-23

Lab In-charge Details :-Prof.S.K.Umathe

  • Equipment
  • Static IDMT 3 sec.
  • Static 3 phase O/C and E/F relay ( APR-41)
  • STATIC RESTRICTING EARTH FAULT RELAY
  • PERCENTAGE BIASED DIFFERENTIAL RELAY
  • STATIC OVER VOLATGE REALY
  • DEFINITE TIME REVERSE POWER RELAY
  • DEFINITE TIME 3 PHASE RELAY
  • SINGLE ELEMENT O/C AND E/F DIRECTIONAL IDMT RELAY
  • POWER SUPPLY
  • RHEOSTAT
  • RHEOSTAT
  • INTERVAL METER
  • CURRENT TRANSFOMER
  • CURRENT TRANSFORMER
  • AUXILIARY CT RATION
  • AMMETER
  • AMMETER
  • DIMMEERSTAT
  • Equipment
  • Static IDMT 3 sec.
  • Static 3 phase O/C and E/F relay ( APR-41)
  • STATIC RESTRICTING EARTH FAULT RELAY
  • PERCENTAGE BIASED DIFFERENTIAL RELAY
  • STATIC OVER VOLATGE REALY
  • DEFINITE TIME REVERSE POWER RELAY
  • DEFINITE TIME 3 PHASE RELAY
  • SINGLE ELEMENT O/C AND E/F DIRECTIONAL IDMT RELAY
  • POWER SUPPLY
  • RHEOSTAT
  • RHEOSTAT
  • INTERVAL METER
  • CURRENT TRANSFOMER
  • CURRENT TRANSFORMER
  • AUXILIARY CT RATION
  • AMMETER
  • AMMETER
  • DIMMEERSTAT
  • DIMMERSTAT
  • DIMMERSTAT
  • DIMMERSTAT
  • RHEOSTAT
  • RHEOSTAT
  • AMMETER
  • VOLTMETER
  • PHASE SHIFTING TRANSFORMER
  • LOADING RHEOSTAT
  • IMPEDANCE RELAY
  • NON-DIRECTIONAL IDMT RELAY
  • AMMETER
  • VOLTMETER
  • VOLTMEETR
  • MULTIMETER
  • CURRENT TRANSFORMER
  • CENTRE TAP TRANSFORMER
  • STOP WATCH
  • RHEOSTAT

No. of devices available in the laboratories:- 49

Lab utilization(Area of the Laboratory):-35m2

Project/ Practical conducted in the Laboratory.:- UG/PG

List of the Software available or installed in the laboratory.:-No Software

Electric Drives Laboratory  : C-23

  • Name of the Laboratory : Electric Drives Laboratory
  • No of devices available in the laboratories:- 12
  • Lab utilization(Area of the Laboratory):-35m2

Project/ Practical conducted in the Laboratory.:-

  1. To study IPM based power module .(PEC16 DSM01)
  2. To study the speed control of dc motor using four quadrant chopper.
  3. To study the constant V/F speed control method of 3 Ø induction motor using three phase inverter.
  4. To control the speed of BLDC motor 1) Open Loop control 2) Closed Loop Control
  5. To develop a Simulink model for the transformation of 3-phase a-b-c variables toq-d variables.
  6. To study the Eurotherm 690+series A.C Drive.
  7. To study the VVVF control of Induction Motor using Eurotherm AC Drive
  8. To study the Speed Sensorless control of Induction motor using Eurotherm AC Drive.
  9. To study Eurotherm 590+ series D.C Drive.
  10. To study the Switched Reluctance Motor Drive.
  11. To generate a PWM to drive a single quadrant chopper and test it with DSP PWM testing unit.
  12. To generate a PWM to drive second quadrant chopper and test it with DSP PWM testing unit
  13. To study control of 3-phase AC Induction Motor by using closed loop PI
  14. To control the AC Induction Motor by using Space vector modulation Technique.
  15. To study space vector closed loop PI control for Induction Motor.

List of the Software available or installed in the laboratory.:-

SRM Module of Motor Pro software

1.Lenovo-3pc- Installed

2.Acer-1pc- Installed

RS Logix Software

1.Lenovo-1Pc-Installed

Lab In-charge Details :-Dr.Swapnil Khubalkar

 

Workshop Laboratory: - C-26

  •  Name of the Laboratory:- Electrical Workshop Project Laboratory
  • Configuration of the devices available in the laboratory:Clamp tester, clamp on earth /ground tester,Dimmerstat, Transformer, Powersupply, Induction motor, Digital Multimeter, Dimmerstat, Ammeter, Winding Machine,Lux meter
  • of devices available in the laboratories:- 41
  • Lab utilization(Area of the Laboratory):-91.23 (Sqm.)
  • Project/ Practical conducted in the Laboratory:- Electrical Workshop Practical
  • List of the Software available or installed in the laboratory:- MATLAB , P-SIM Software&Power World Simulator

Lab In-charge Details :- Prof. Suraj Dudhe